you can check that from the inventoryagent.log. Hi, Please redownload the attachment ,import the MOF file into client settings ,it should work for you this time. If so how did you, Please assist, I'm running this and I can see the entry in the config man on the targeted computer but I do not see the log file being created. ex: instead of AD\GroupA, report shows UserA, UserB (which are the members of AD\GroupA). Give a try on different OS and let me know the results. To replace these, search for Test.local and specify your domain name. Hi Matt, SQL query is given in this blog post. 3.Run SQL query /report to get members of local administrators group. All is OK but nothing in DB. hi Jose, Hi Eswar ... could you please edit the script to fetch the Accounts State "Disabled". Looking at the InvetoryAgentlog you can see it is running the query: select _class, _path, _relpath, account, domain, name, disabled, type from cm_localgroupmembers. For database reporting, check the client inventory log if the wmi namespace picked up and sent the inventory to site server. join v_r_system sys1 on sys1.resourceid=lgm.resourceid 5/13/2018 6:20:00 PM - Completed populating cm_localgroupmembers I'v turned it on, waited for the next cycle, I can see the CI running in clients, but I still get the "NULL" on the db tablev_gs_localgroupmembers0. WQL Queries * tested in the SCCM Console, under the Queries node * many other queries in PDF. join v_r_system sys1 on sys1.resourceid=lgm.resourceid Eswar - Ok will use the new MOF file (SCCMLocalGroupMembers.MOF) into ciient settings and see, if sql script will work. If you want to deploy software to a particular AD user group then create a User Collection and use the following Query Statement: Remember to make sure you have Discovery set up on your AD or specific OU containing groups. I started to follow above blogs few days ago for my task, but for some reason these URL’s not active .So during my online search,i found few other blogs that talk about this solution . strUserPath = arrUserBits(0) & "/" & arrUserBits(1) Include Membership collection Rule SQL Query. I joined the machineID from the table with the existing views resourceID and able to see the data but the view never gets created. I have tried this solution very long ago for some of my customers which worked fantastic , but i did not blog about this as there are already posts available online. SCCM Clients Collections Clients not approved select SMS_R_SYSTEM.ResourceID, SMS_R_SYSTEM.ResourceType, SMS_R_SYSTEM.Name, SMS_R_SYSTEM.SMSUniqueIdentifier, SMS_R_SYSTEM.ResourceDomainORWorkgroup, SMS_R_SYSTEM.Client from SMS_R_System … 1. If you do not wish to enable incremental updates, adjust the full update schedule to fit your environment. Any way that can push the clients report to SCCM in faster way. Wait for client to receive new client device settings and configuration baseline to create wmi instance followed by client inventory . They will help you to figure out where the issue. is there a way to confirm that this is an inherent issue with the latest CB versions? This speeds up software installation times. Enabling delta discovery for Active Directory groups. I am having a bit of trouble with this DCM script - I have imported and configured everything fine, and it actually works great within DCM. Attribute: System OU Name. Our computers are not in English but because you are looking into the WMI classes it shouldn't matter isn't it? Secondly if I view same devices in Resource Explorer I only see 5 members under the LocalMembers hardware inventory item. oDataObject.Properties_.add "Name" , wbemCimtypeString try with this link http://eskonr.com/wp-content/uploads/2017/03/SCCMLocalGroupMembers.zip . Ran into the same issue. Create WQL Query under SCCM Monitoring Workspace . UUGN.User_Group_Name0 = ‘gartek\domain admins’ order by U.Unique_User_Name0. did numerous of hardware inventories on my client. Hi Eswar, thank you for this great work. On client machine after the policy ,assigned configuration baseline is compliant. sccm query for workstations To use you will need to create a new collection and add as a Membership Query Rule. I don't quite get your next step that says "Logging information by Script".. many thanks!! I tried in CMCB 1802 and it works .Have you tried checking client wmi if there is any info loaded there also check the inventoryagent.log for further troubleshooting. select SMS_R_SYSTEM.ResourceID, SMS_R_SYSTEM.ResourceType, SMS_R_SYSTEM.Name, SMS_R_SYSTEM.SMSUniqueIdentifier, SMS_R_SYSTEM.ResourceDomainORWorkgroup, SMS_R_SYSTEM.Client from SMS_R_System where SMS_R_System.SecurityGroupName = "Contoso\\Test_Security_Group" So i started creating configuration items ,configuration baseline and do changes to client agent settings (MOF file) ,generate report . join v_gs_workstation_status ws on ws.resourceid=lgm.resourceid Hey, I've added the .MOF file to default client settings, added the .CAB file. 5/13/2018 6:20:00 PM - Found 24 Local Groups This was very helpful for our security audit. For the uninstall collections create a query to list the devices that have the application installed and the device/user is no longer a member of the AD group. This complexity can make it difficult to use, especially when you just want to deploy an application. Seems to be the case here. 4/10/2020 11:59:09 AM - Not a Domain Controller, Continuing "output of the script into SCCMLocalGroupMembers.log in C:\windows\temp folder:". Perhaps I am going about it the wrong way, but I cannot get the queries to work; I keep getting a syntax error. excluding the disabled properties generated the proper info. https://social.technet.microsoft.com/Forums/en-US/7f1962ed-9f7b-404b-83d0-88880d3b2141/collecting-local-admin-members-through-hardware-inventory-mof?forum=configmanagergeneral&prof=required. Any other messages are welcome. To save time, we are going to assume that you have already imported an MSI into SCCM. I get page error 404. I havent looked at the script for disabled accounts. We are looking for new authors. Is there a way to expand the groups? 5/13/2018 6:20:00 PM - Found a total of 19 Names within those 24 groups thanks for the comment. Please look at this to get shares on computer https://social.technet.microsoft.com/Forums/exchange/en-US/38bc16d7-2437-46fb-8c1b-e51f4697c490/sccm-report-for-finding-machines-with-local-shares?forum=configmgrgeneral. The steps above can be quite repetitive if you need to create many AD-based collections. To do this click Administration>Discovery Methods>Active Directory Group Discovery. LocalGroupMembers (cm_LocalGroupMembers). Step 1: Copy the MOF file from download section to your SCCM server,import the MOF file into default client agent settings—>Hardware Inventory in your SCCM server (CAS if you have else primary site )  ,de-select the settings  in default client agent settings for localgroupmembers . The script will prompt you for any information needed. For standardization, name your new collection the same as your security group. Set oDataObject = oServices.Get I've check dataldr.log and no errors. Seems to be the case here. Thats when Microsoft rolls out changes that drastically affect companies that have yet to upgrade older Office versions. Did it work? hi, Read 4sysops without ads and for free by becoming a member! EX: APP_Adobe Flash Player", "OU=Software Distribution,DC=Test,DC=LOCAL", 'select *  from  SMS_R_User where SMS_R_User.UserGroupName = "', "Name='$CollectionName' and CollectionType = '$CollectionType'", "\\Localhost\$Namespace`:SMS_CollectionRuleQuery", #Commit changes and initiate the collection evaluator, Amazon cloud - Part 5: Networking and monitoring. Collection based on AD Group query taking forever. Create a new device collection. hi eswar, I, need SCCM 1902, SQL Views for Local Group Members & SQL Query also. Third, the SCCMLocalGroupMembers.log does in fact tell me it found 19 members and populated the WMI namespace but still no luck. By using PowerShell, we can automate these tasks. But i don't get any data when i Query "v_gs_localgroupmembers0" ; it stays empty. However, I got a problem on the report as the number of PC in report listed (around 100 and use the queries provided) is not same as the compliant (check in the deployment status view and around 397 assets). For examle: Russian, Italian, English and Germany can you login to one of the client PC and see if there is any WMI namespace created and see cm_localgroupmembers ? Click OK until you are back at the Device Collection Wizard. This menu can be found in the top left of the console. Hence the need to inject the OS into the report so I can separate. Domain0: S-1-5-21-3623811015-3361044348-30300820-1013 Hi, In some client machine the WMI class CM_Localgroupmember is not getting created? Not sure where, I am going wrong. Collection: Namespace = \\.\root\cimv2; Query = SELECT __CLASS, __PATH, __RELPATH, Account, Domain, Name, Category, Type FROM cm_LocalGroupMembers; Timeout = 600 secs. Since we have already started the process I need to go back and check the PC's already done. $ClassFound, (sorry, would give a shout out if I remembered where I found this script - I just modified it for the WMI Object I was looking for). Hoping this can find it's way to people that are running into troubles with this, or needing help with tweaks. Appreciated and thanks for your feedback. You can reply on SQL view that are discovered by AD system/security groups . Also for international Windows users: if you want to make a proper select with the WHERE clause you should add N before the international name of your Administrators group, in my case it is Your understanding is pretty close. click next (leave default OS settings) ,next, on settings page ,add new with following information. try using report builder and it easy method to edit reports or you can use visual studio . Hey Eswar, Error 0x80041002". I Am having the same issue. This guide covers creating groups and collections and describes a sample deployment. Set wshNetwork = WScript.CreateObject( "WScript.Network" ) strComputer = wshNetwork.ComputerName Many thanks if there is wmi namespace and data available and if you have extended the MOF (client agent settings), client should pick the changes and report back the data. Oh and I don't need to inject the PC name, just the OS. This blog post will describe how to do a script to create SCCM Collections based on AD OU. The DB has the field created but everything is empty. You can also subscribe without commenting. SCCM report User member of What collections For Application Deployment . I've checked your code and haven't seen why this is not working. Hi - I was testing this at home lab. Applied baseline to a collection of 21 servers. One thing that I decided to do differently in my environment to get some real reporting back on my baseline was to change my CI a bit. Bamrung commented on Error changing time zone in Windows Server 2019: Use the command line or PowerShell instead 28 minutes ago, Panny commented on Strings in PowerShell – Replace, compare, concatenate, split, substring 12 hours ago. Is the view created and is empty? Finding the users/groups who are member of  local administrator group manually or scripting is tedious task on all servers .If you are managing the devices with configuration manager ,you can leverage Configmgr tool to get this task done so easily . Also do we get your support to collect all shares on servers with share & NTFS permissions. Setup this script to run as a scheduled task. Paolo Maffezzoli posted an update 23 hours, 19 minutes ago, Paolo Maffezzoli posted an update 23 hours, 21 minutes ago. I looked at the table dependencies and there at no dependent views for the localgroupMembers table. It does have a few hardcoded values in it. Do you have CAS ? On the General tab of the Create Query Wizard, specify a unique name and, optionally, a comment for the query. Please ask IT administration questions in the forums. i suspect the script is not able to read or understand the GUID S-1-5-21-3623811015-3361044348-30300820-1013 values and it is always difficult to translate the values from GUID to user names. I'm able to get members of local administrators group. Name= arrUserBits(1) Have you tried importing baseline into 1902? This will save time as you do not have to jump between MMCs as often, and you can easily delegate app management. I am attaching the configuration baseline cab file here for you to download ,extract ,import into your configmgr 2012 or configmgr current branch 1610 and simply deploy to your required collection, import MOF file into client agent settings for hardware inventory. I try to deploy the script and no luck so far, also if I run the vbs itself on the target computer I can't find any class populated named as in the script, what should I check first? , lgm.category0 [Account Type] Logging information by script means ,when the script run on the client, it will log the information into SCCMLocalGroupMembers.log in C:\windows\temp folder which is stated in the blog post as This SQL Query will help you in using ‘When’ and ‘then‘ syntax. Script 1 will get you the information about users/members who are member of administrators group ONLY and script 2 will get you members of all locally created groups. Why do you want to inject the PC name into the script? where lgm.name0='Administrators' The following WQL query statement can be used include an Active Directory Group in a Configuration Manager Collection. Did you check the client logs if there are any entries in WMI for local group membership created? Domain users from AD1 How to Find Users and thier AD groups in SQL Server - SQL Server DBA Tutorial This video illustrates Following: 1- How to find members of an Active Directory group using SQL Server Management studio (SSMS) 2- How to find members of an Active directory group using T-SQL Script 3- How to find which Active directory group a particular user belong to using T-SQL. Step 2: From configuration manager console, assets and compliance , compliance settings right click configuration item ,create new ,type Name ,description. For compliance baseline ,you can try to trigger baseline on the client manually ,check if it is compliant ,if so ,try to run the inventory action ,monitor the results in inventoryagent.log and then on SCCM database. Is there another method I should be using? adsgdis.log doesn't show any clear indication of an issue during delta. Query 2: List members of the local Administrators group on specific client: select sys1.netbios_name0 I have posted my issue here also with some of the troubleshooting steps. Required fields are marked *. With both of these settings configured, SCCM will be able to see our Active Directory resources. Hi Eswar, We have all the procedure created, but now the client asks us to have the powershell script instead of vbs, do you have any examples to be able to use the baseline using a powershell script? Linking an AD security group to a SCCM collection, "What is the name of the Application group? On the Query Rule properties window, you can now view the query. Any idea? oDataObject.Properties_.add "Type" , wbemCimtypeString Type: String: Aliases: Name: Position: Named: Default value: None : Accept pipeline input: False: … Can you describe the variables involved in the time it takes for a system to be added to an AD Security Group setup in this way to actually receive an application on the client? ,lgm.name0 [Name of the local Group] You can see it fail in the log when trying to send it. These 2 will help you what is going on. In SCCMLocalGroupMembers.log files for all of those 21 servers I checked, I can see something similar to below, 5/13/2018 6:20:00 PM - Script Started can you check the log for any errors there to create the wmi class? End If, arrUserBits = Split(strUserPath, "/") Create configuration item,configuration baseline and deploy to collection on recurring basis. If you do not have any custom client agent settings in your environment ,you can enable this settings in default client agent settings. Quite common (based on all the blog-articles) is to set an Incremental update for … It is a software deploying, application packing, OS installing, and cappuccino making machine (currently in testing, expected in System Center 2015). But getting below error, "GetPropertyListForClassName - Failed to get class 'C00000000_0000_0000_0000_000000000011' from WMI namespace. I dont have any powershell script that does the similar function however you can create one from the vb script as sample. We can now specify the security group that will define our query. Many organizations still use Active Directory groups or Organisational Unit to do operational tasks in SCCM. Import the required class definitions and then try to import the settings again. I have updated the MOF file . It attempts to exclude but still fails in sending to the sccm MP. Thanks! Use this procedure to create a query in Configuration Manager. This query simple checks to see if the Client Activity Status is equal to zero. I'd rather not be running the script unless it needs to be run, and I don't need to run it if the WMI object exists. so I have a few collections for software deployment based on AD group membership (so the Service Desk can easily deploy software). Domain0:S-1-5-21-3623811015-3361044348-30300820-1013 dataldr.log is no error. Many will tell that it’s not the most efficient way to do it but it’s effective for some. you will get the OS information from SCCM database with resourceID/hostname from v_r_system_Valid or v_gs_operating_system. A while ago I had to collect the members of the local administrators group via ConfigMgr. several ways to accomplish things depends on the needs. In WMI i see data. On the Completion window click Close. Check your link, the cab file is missing fromt the zip. Now of course we are being asked to expand the report a bit and I was curious if this could\should be done through the addition of items in the MOF or through other means... We are asked to also provide the Description of the Local Account, whether it is Locked Out (True\False), the Last Login, when the last time the password was changed for the account and if the Password is Expired. Type1 = "Local" Edited Jan 10, 2016 at 08:11 … order by sys1.netbios_name0, lgm.name0, lgm.account0. Query for Users within a Security Group Using a Variable. I've just got through this myself. I would lilke to know if it's something I'm doing or a change in the way custom views are created. So a customer of mine wanted a report from configuration manager to list primary devices for their users. Any suggestions, Do you have log created and wmi instance name? oDataObject.Properties_.add "Domain" , wbemCimtypeString I tried to do this through query builder but without success. SELECT DISTINCT SMS_R_System.NetbiosName, SMS_G_System_OPERATING_SYSTEM.BuildNumber FROM SMS_R_System INNER JOIN … Hi, ,lgm.domain0 [Domain for Account] This can be confirmed by running the wmi query through powershell. Can be set to Incremental defined as "periodically" - takes about a minute. order by sys1.netbios_name0, lgm.name0, lgm.account0. Linking security groups to SCCM deployments will give your environment flexibility with application installations. arrUserBits = Split(strUserPath, "/") You can validate this in powershell as well by running: Get-wmiobject -query "select _class, _path, _relpath, account, domain, name, disabled, type from cm_localgroupmembers". if you have deployed the baseline onetime ,you will not get updated results . Why is this needed? Thank you for your thoughts! You can download the files from http://eskonr.com/wp-content/uploads/2017/03/SCCMLocalGroupMembers.zip or simply download the baseline and import into SCCM but dont forget to update mof files. I ran the configuration baseline after adding the mof file and adding the localadmin hardware inventory class but i am not finding the v_gs_localgroupmembers0 table in the DB. Note: This task can be achieved in 2 ways ,either by deploying script as package or deploying the script using baseline method ,but Pre-requisite ,is recurring deployment, or Recurring DCM Baseline/CI. Check attached images. ,lgm.account0 as [Account Contained within the Group] Also can you run the script manually on the client that would create wmi instance. Values should be available when you click the value button. The Information which is stored SQL views that start with V_GS comes from inventory. what this baseline does it ,when you run ,it pipe the information into wmi and inventory agent will pick this information and send it to site server. 2. join v_gs_workstation_status ws on ws.resourceid=lgm.resourceid His main focus is on Device Management technologies like SCCM, Intune, SCOM and Powershell. "S-1-5-21-3623811015-3361044348-30300820-1013" All the configuration went well. Specify a limiting collection. Did the script ran successfully? These collections demonstrate different queries you can use to create all the collection you need. oDataObject.Properties_("Name").Qualifiers_.add "key" , True Name0:S-1-5-21-3623811015-3361044348-30300820-1013. When you … but still nothing in DB. It is possible to edit the script to get disabled accounts as well . If you have any questions about using Active Directory with SCCM (or about using this script below), just leave a comment! please ignore it ,and thanks f, https://social.technet.microsoft.com/Forums/exchange/en-US/38bc16d7-2437-46fb-8c1b-e51f4697c490/sccm-report-for-finding-machines-with-local-shares?forum=configmgrgeneral, https://social.technet.microsoft.com/Forums/en-US/7f1962ed-9f7b-404b-83d0-88880d3b2141/collecting-local-admin-members-through-hardware-inventory-mof?forum=configmanagergeneral&prof=required, http://eskonr.com/wp-content/uploads/2017/03/Local-Admin-BaselineMOF-file.zip, http://eskonr.com/wp-content/uploads/2017/03/SCCMLocalGroupMembers.zip, http://eskonr.com/2017/03/sccm-configmgr-report-for-local-admins-and-local-group-members/, Creative Commons Attribution 4.0 International License. I mean, if i report a list of groups that are members of the local Administrators group, can I report the expanded users list? Hi, If the device has multiple users in admin group then you get multiple rows for the same computer . Thanks for very good explanation with example code. oNewObject.Put_ , lgm.domain0 [Domain for Account] Then, added the VBScript from Sherry as my remediation. The heavy lifting is done with a PowerShell script. Next. Thanks! It can be possible but you get domain name in the V_R_system table that makes it different . If Domain = strComputer Then Recommended for these deployment types. Hi Adrien, Hi Jason, I've follow your steps, looks like I have the WMI created but I don't see anything on either the ressource explorer or directly from the computer. All queries tested in SCCM Current Branch 1902. Open the SQL Management Studio. If you search online with subject line ,you will mostly hit TechNet forum/blogs that refer to the following links. Specify your application deployment settings in the wizard. Open up Query editor and throw this bad boy in there: So what you’ll want to do at the end of this, where it says ‘YOUR COLLECTION ID HERE’ is to put your collection ID there. Solution that was provided by Sherry was to create configuration item/configuration baseline with vbscript ,deploy this to collection ,import mof file into client agent settings to pull custom wmi changes that made by script,run report to get the required information. Did you check the logs on the computer ? Set oLocation = CreateObject("WbemScripting.SWbemLocator"), Set oServices = oLocation.ConnectServer(,"root\cimv2") SCCM Query Collection List. I do have a question as I am a bit lost.. After the baseline configuration shows as compliant, how do I retrieve that information whether by sql query or report in SCCM or other wise? Domain users from AD2. What are some troubleshooting steps for group memberships not being discovered with the delta discovery? Thanks for answering, look like my data are incorrect from the inventoryagent.log. This script is designed to be run from the Configuration Manager Server. If UBound(arrUserBits) = 2 Then 4/10/2020 11:59:09 AM - Starting to populate cm_localgroupmembers If I'm correct here, it could potentially take up to 2 weeks for an environment left in the Default configuration. Great blog post! did you check dataldr.log if the mof changes you made are successfully compiled ? Everything I found was related to option 2) Get members of all groups, Could you please have a look and re-add the scripts/files which are needed for option 1 ? Under Edit Query Statement, select Criteria and Add (star button), and then press Select. Hi, Now, my manager asked me for that info. This is hos a collection query for linux / unix computers look like in SCCM. I definately see the class in wbemtest. What should I do? Thanks so much for the article and it do help a lot. Hi Erik, This is a collection query for a with all Mac computers as members of the collection Incase of any issues with creation of wmi class or not seeing any inventory in the database, please check the log if the baseline has created any wmi class or not. If you run: Get-WmiObject cm_localGroupMembers, you will see the disabled property is not set in the object. Regards, Eswar, Hi NAFJU, Thanks for the kind words and appreciate it. Query 1: List all clients with members of the local Administrators group: select sys1.netbios_name0 from v_gs_localgroupmembers0 lgm If the default query will not even display the security group I assume my user collection query to display all "Leaderships" members will not work either? This entry was posted in ConfigMgr, Support and tagged database, duplicated objects, query, sccm on December 11, 2012 by Adrian Kielbowicz. Where are you importing the client settings ? Is there a way to inject the current OS of the PC in this script? try with this link http://eskonr.com/wp-content/uploads/2017/03/SCCMLocalGroupMembers.zip SCCM ConfigMgr report for local admins and local group members, Hi Rome, What certificates are you referring to? Client inventory settings are set to run per day. I would strongly suggest you go with configuration item and make it recurring instead of scheduling it for 1 time. I also added a PowerShell script that helps create AD group-based SCCM collections. If you want all the users in same row ,you can use something forxml code in SQL so you get right number there. Not yet.I will check in this week. output of the script logged into SCCMLocalGroupMembers.log in C:\windows\temp folder: Now you will see a wmi class created in root\cimv2 with cm_localgroupmembers. I can query the tables with a direct query to the database and the data is being collected. it worked for me but it looks like the it is only for English but not for other languages. Deploying a preexisting application to our AD linked collection. from v_gs_localgroupmembers0 lgm This guide covers creating groups and collections and describes a sample deployment. $ClassInfo = Get-WMIObject CM_LocalGroupMembers -ErrorAction SilentlyContinue -ErrorVariable wmiclasserror oNewObject.Delete_, ' Create data class structure Try with this http://eskonr.com/wp-content/uploads/2017/03/SCCMLocalGroupMembers.zip.

Tillamook Marionberry Ice Cream, Audient Id14 Vs Apogee Duet, Amazon It Support Engineer I Salary, Rooftop Snipers 76 Games, Remington Side By Side Serial Number Lookup, Kphx Ils Frequencies, Virginia Local Government Employee Salaries, 3 Or 4 Fins On A Rocket,